How to measure protein stability in solution?

To measure protein stability in solution, you can use FIDA (Flow Induced Dispersion Analysis). FIDA measures the size of your protein in any buffer system and shows whether it has unfolded, aggregated or changed its oligomeric state.

How does FIDA measure protein stability?

FIDA measures the hydrodynamic radius of the protein. Folded proteins are compact, with a smaller hydrodynamic radius. Unfolded or denatured proteins expand, with a larger hydrodynamic radius. This is useful for studying stability, misfolding diseases (like Alzheimer's) or thermal unfolding. When proteins form dimers, oligomers or aggregates, the hydrodynamic radius increases.

FIDA measures the stability of your protein in any buffer system, using only 40 nL, in minutes. It works both with the intrinsic fluorescence of the protein, measured with the UV detector, so no label is needed, and with fluorescently labelled proteins. You simply load the protein into the Fida instrument, run your experiment, and the readout will tell you the size of your protein and, for example, whether there are any aggregates. If the protein structure is known, use the PDB Correlator, a feature of the Fidabio software, to extract information on the oligomeric state of the protein. The Hydrodynamic radius course in the Sample Characterization & QC section of the Fidabio Learning Hub covers how size reflects folding and aggregation.

Read the application note Screening conformational stability using only nanograms of protein.

How to measure protein unfolding?

FIDA can be used to measure the unfolding of a protein through chemical denaturation. As there is no limitation on the matrix, the sample can be measured in various chemical denaturants, such as urea or guanidinium chloride, to unfold the protein.

Each measurement reports the hydrodynamic radius and the intrinsic fluorescence of the protein at the same time, label-free, from about 40 ng of protein per data point. The protein can be dispersed into the denaturant inside the capillary, which removes the need for a manual dilution series, and the resulting unfolding curves give the denaturation midpoint (Cm) and the Gibbs free energy of unfolding (ΔG°), as shown in the publication Quantification of Structural Integrity and Stability Using Nanograms of Protein by Flow-Induced Dispersion Analysis (Molecules, 2022).

For example, in the application note Assessment of protein Stability and Functionality by Flow Induced Dispersion Analysis, urea at around 4.0 M unfolded human serum albumin (HSA), seen as an increase in size from 3.5 nm to 6.2 nm, in line with a similar study using small angle X-ray scattering (SAXS). The intrinsic fluorescence of HSA changed at 1.5 M urea, indicating local structural changes before the overall unfolding, and binding of HSA to fluorescein declined with increasing urea concentration, showing loss of functionality.

How to measure the thermodynamic stability of amyloid fibrils?

FIDA measures the thermodynamic stability of amyloid fibrils through chemical depolymerisation. As urea depolymerises the fibrils, FIDA quantifies the soluble monomer, and from this the free energy of fibril stability (ΔG) is derived.

For example, the publication Thermodynamic characterization of amyloid polymorphism by microfluidic transient incomplete separation (Chemical Science, 2024) quantified the stability differences between α-synuclein fibril polymorphs. The publication Thermodynamic Stability Modulates Chaperone-Mediated Disaggregation of α-Synuclein Fibrils (Chemical Science, 2025) found that the efficiency of chaperone disaggregation correlated negatively with fibril thermodynamic stability.

How FIDA measures fibril length, oligomers and binding to fibrils is covered in how to measure amyloid fibril length and binding in solution.

Can FIDA be used to measure thermal stability of proteins?

To an extent, yes. FIDA can control the temperature in the Fida instrument in three different compartments: sample tray, buffer tray and the capillary chamber. In the sample and buffer trays the temperature can be controlled between 5 and 55 °C, or between 5 and 95 °C, depending on the Fida instrument. In the capillary chamber the temperature can be controlled between 15 and 55 °C. The figures for each instrument are in the Fida instruments comparison table.

Frequently asked questions

How much protein does a FIDA stability measurement use?

About 40 nL per measurement, in minutes. Chemical unfolding curves use about 40 ng of protein per data point.

Does FIDA need a fluorescent label to measure unfolding?

No. With the UV-fluorescence detector, FIDA uses the intrinsic fluorescence of the protein, so the unfolding measurement is label-free.

How to optimise protein storage?

You can use the Fida instrument to measure the stability of your protein. This means that you can store your protein in different ways and, after storing for some time, check the stability of the protein. The storage method giving the same or similar result as when the protein was freshly prepared will be the optimal storage condition.

Related resources

Want to see more stability work with FIDA? See the poster An automated methodology for assesment of protein stability using nanograms of protein and the application note Characterization of Conformational Changes by flow induced dispersion analysis.

New to protein stability with FIDA? What is hydrodynamic radius? explains the size readout, What is protein aggregation? and What is the polydispersity index (PDI)? explain the other signs of an unstable sample, and What is protein oligomerisation? covers changes in oligomeric state. To find out whether FIDA fits your stability or formulation work, book a discovery call.